Anti-Corrosive Pipe Wrapping Tape
We are a leading Manufacturer of pipewrap bt hot applied anti-corrosive bituminous tape and pipewrap ct hot applied anti-corrosive coal tar tape from New Delhi, India.
PipeWrap BT Hot Applied Anti-Corrosive Bituminous Tape
Get Latest Price
Product Brochure
Product Details:
Brand | PipeWrap |
Tensile Strength Crosswise for 2 mm | 50 |
Elongation Minimum Lengthwise for 2 mm | 100% |
Elongation Minimum Crosswise for 2 mm | 100% |
Softening Point | 65 - 121 |
Penetration at 25 Degree C, 100 grm, 5 sec | 3 - 20 |
Heat Resistance | Does not dip at 100 Degree C |
Tensile Strength Lengthwise for 2 mm | 70 |
2 mm PipeWrap® BT is five layer without fiber glass inner core, whereas, 3 / 4 mm thick PipeWrap® BT is seven layer tape with two inner cores; top core is of tough 45 gsm fiber glass and the bottom core is of 15 micron high tensile strength HMHDPE.
Application:
- Coating material for drinking water pipelines, fire fighting pipelines, raw water pipelines in thermal plants etc.
- Applied on buried and immersed pipes, fittings and appurtenances to protect them from high corrosive environment
Advantages:
- Coating material for drinking water pipelines, fire fighting pipelines, raw water pipelines in thermal plants etc.
- Applied on buried and immersed pipes, fittings and appurtenances to protect them from high corrosive environment
Surface Preparation:
- Remove dust, flakes, oil, grease or other loose foreign particles by blasting, wire brush or compressed air.
- Leave 200 mm from pipe ends for welding joints. Coat and wrap such left over part of pipe at site after welding and hydro testing.
Application of Material:
- Apply ShaliPrime PW BT on cleaned surface at 0.30 L / m2 to get DFT of 30 microns.
- Allow the primed surface to touch dry, which may take 5 - 15 minutes.
- Remove PE film and show the flame of butane gas torch on to the surfaces till it becomes glossy-smooth
- Coat PipeWrap® BT on the primed surface. Provide overlap of 25 mm between two adjoining layers. Wrap spirally and apply sufficient tension to ensure good adhesion and avoid pockets and bridging to meet holiday detection requirement. Tape joint shall face downward on outside of lap joint.
- Complete necessary welding and testing of the joint before coating
- Recommend to apply at the time of pipe erection and lowering inside trenches to avoid any damage.
Health & Safety:
- Avoid contact with skin / eyes and avoid swallowing
- Ensure adequate ventilation and avoid inhalation of vapour
- Wear suitable protective clothing, gloves and eye protection
- In case of skin contact, rinse with plenty of clean water, then cleanse with soap and water. Do not use solvent to clean the contacted area
- In case of eye contact, wash with plenty of clean water and seek medical advice.
- If swallowed, seek medical attention immediately. Do not induce vomiting
Packing:
- Available in 2 mm, 3 mm and 4 mm thickness with width of 250 mm, 500 mm and 1000 mm. Each roll of 2 mm tape consists of 20 Mtr length, whereas each of roll of 3 mm & 4 mm tape consists of 10 Mtr length
Storage:
- Keep under shed, away from heat. Do not stack more than three rolls in one column.
Get Best QuoteRequest A Callback
PipeWrap CT Hot Applied Anti-Corrosive Coal Tar Tape
Get Latest Price
Product Brochure
Product Details:
Brand | PipeWrap |
Weight | 1.50 Kg / m2 / mm +- 10% |
Solubility of Coal Tar Based Tape in Petrol | Max. 5% wt in 24 Hrs |
Adhesion Test on Applied Tape on Steel Pipe | Passes |
Cathodic Disbondment test with Applied Tape on Steel | < 5 mm radius from the edge of 6 mm holiday |
Holiday Test, of Thickness | 10 kV at 2 mm, 12 kV at 3 mm, 15 kV at 4 mm |
Tensile Strength Crosswise for 4 mm | 80 |
Elongation Crosswise for 4 mm | 15%, minimum |
Maximum Filler | 35% |
Minimum Softening Point | 65 Degree C |
Penetration at 25 Degree C, 100 gm, 5 sec | Min. 1, Max. 9 |
Filler | 20 - 30% |
Holiday Test for 4 mm | min. 12.0 kV |
Service Temperature of Tape | Max. 60 Degree C |
Breaking Load in the Longitudinal Direction for the following Thickness of Tape | 3.0 N / mm at 2 mm, 4.0 N / mm at 3 mm, 5.0 N / mm at 5 mm |
Pliability at 15 Degree C | Does not break |
Tensile Strength Lengthwise for 4 mm | 250 |
Direct Impact Test, Disbonded Area | 10,000 mm2 |
Holiday Test For 2 mm | Min. 4.5 kV |
Elongation Lengthwise for 4 mm | 15%, minimum |
Maximum Softening Point | 121 Degree C |
Minimum Filler | 20% |
Application:
- Coating material for drinking water pipelines, fire fighting pipelines, raw water pipelines in thermal plants, oil and gas pipelines.
- Applied on buried and immersed pipes, fittings and appurtenances to protect them from high corrosive environment
Advantages:
- Resist Moisture
- Resist bacterial growth
- Most effective solutions for refurbishment, repair and maintenance of existing pipelines, specially in-situ repair
Surface Preparation:
- Remove dust, flakes, oil, grease and mill scales by blasting, to achieve SA 2½ as per Swedish Specification
- Leave 200 mm from pipe ends for welding joints. Coat and wrap such left over part of pipe at site after welding and hydro testing.
Application of Material:
- Apply ShaliPrime PW CT on cleaned surface at 100 - 120 Ml / m2 (depending upon surface condition) to get DFT of about 30 microns.
- Allow the primed surface to touch dry, which may take 5 - 15 minutes
- Remove PE film and show the flame of butane gas torch on to the surfaces till it becomes glossy-smooth.
- Coat PipeWrap® CT on the primed surface. Provide overlap minimum 12 mm between two adjoining layers. Wrap spirally and apply sufficient tension to ensure good adhesion and avoid pockets and bridging to meet holiday detection requirement. Tape joint shall face downward on outside of lap joint
- Complete necessary welding and testing of the joint before coating
- Recommend to apply at the time of pipe erection and lowering inside trenches to avoid any damage.
Health & Safety:
- Avoid contact with skin / eyes and avoid swallowing
- Ensure adequate ventilation and avoid inhalation of vapour
- Wear suitable protective clothing, gloves and eye protection
- In case of skin contact, rinse with plenty of clean water, then cleanse with soap and water. Do not use solvent to clean the contacted area
- In case of eye contact, wash with plenty of clean water and seek medical advice.
- If swallowed, seek medical attention immediately. Do not induce vomiting.